Doses: Difference between revisions

From cleanroom
Jump to navigation Jump to search
No edit summary
Line 1: Line 1:
= 125  kV =
= 125  kV =
{| class="wikitable"
|+125 kV
|-
|
|Si
|InAs<sup>UC</sup>
|InP<sup>UC</sup>
|GaAs<sup>UC</sup>
|SiGe
|-
|A2
|1000
|700
|?
|700
|?
|-
|A4
|1000
|700
|?
|700
|?
|-
|A6
|1200
|?
|?
|?
|?
|-
|El6
|?
|?
|?
|?
|?
|-
|El9
|Pie
|Pie
|Pie
|420
|Pie
|-
|CSAR4
|430
|Pie
|Pie
|Pie
|Pie
|-
|CSAR9
|Pie
|Pie
|Pie
|Pie
|Pie
|-
|CSAR13
|Pie
|Pie
|Pie
|Pie
|Pie
|-
|}
==GaAs==
==GaAs==
A6: 742 uC/cm2 Uniform clearing Beamer base dose/60s dev MIBK dev/10s IPA
A6: 742 uC/cm2 Uniform clearing Beamer base dose/60s dev MIBK dev/10s IPA

Revision as of 20:50, 1 May 2018

125 kV

125 kV
Si InAsUC InPUC GaAsUC SiGe
A2 1000 700 ? 700 ?
A4 1000 700 ? 700 ?
A6 1200 ? ? ? ?
El6 ? ? ? ? ?
El9 Pie Pie Pie 420 Pie
CSAR4 430 Pie Pie Pie Pie
CSAR9 Pie Pie Pie Pie Pie
CSAR13 Pie Pie Pie Pie Pie

GaAs

A6: 742 uC/cm2 Uniform clearing Beamer base dose/60s dev MIBK dev/10s IPA

CSAR13: 420uC/cm2 base dose/24s o-xylene/5s conc. MIBK develop with IPA rinse

EL9: 420uC/cm2 base dose/45s MIBK:IPA develop with IPA rinse

InP

A4.5: 700 uC/cm2 Uniform clearing Beamer base dose/60s MIBK:IPA dev/10s IPA

InAs

Si

CSAR 9: 430 uC/cm2 optimal contrast

A4: 1000 uC/cm2

A6: 1200 uC/cm2 (or 1000 uC/cm2 with longer development? To be tested)

100 kV

GaAs

A6: --- uC/cm2 Uniform clearing Beamer base dose/60s dev MIBK:IPA/10s IPA

CSAR 13: 480uC/cm2 base dose (likely overdosed)/ 24s o-Xylene/5s conc. MIBK develop/IPA rinse

EL9: 380 uC/cm2 base dose/ 45s MIBK:IPA/ 10s IPA rinse

InP

A4.5: 550 uC/cm2 Uniform clearing Beamer base dose/60s MIBK:IPA dev/10s IPA

InAs

Si

CSAR 9: 400 uC/cm2 optimal contrast/ 30s O-Xylene/5s conc. MIBK/IPA

A4: 800 uC/cm2/40s MIBK:IPA dev./10s IPA