Doses: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
Line 155: | Line 155: | ||
== Note == | == Note == | ||
Base dose does not change with resist thickness, developing time does. | Base dose does not change with resist thickness, developing time does. However, if the developing time is fixed, say to 60s, a thinner layer of resist will need lower "base dose", since it's being over developed. |
Revision as of 23:10, 22 June 2018
Si | InAsUC | InPUC | GaAsUC | SiGe | |
A2 | 1000 | 700 | ? | ? | ? |
A4 | 1000 | 700 | ? | 630 | ? |
A6 | 1200 | ? | ? | 760 | ? |
El6 | ? | ? | ? | ? | ? |
El9 | ? | ? | ? | 420 | ? |
CSAR4 | 430 | ? | ? | ? | ? |
CSAR9 | ? | ? | ? | ? | ? |
CSAR13 | 450 | ? | ? | 350 | ? |
50k+A4 | ? | ? | ? | 745 | ? |
Si | InAsUC | InPUC | GaAsUC | SiGe | |
A2 | 900 | ? | 500 | ? | ? |
A4 | 900 | ? | 500 | 630 | ? |
A6 | 1000 | ? | ? | 670 | ? |
El6 | ? | ? | ? | ? | ? |
El9 | ? | ? | ? | ? | ? |
CSAR4 | 400 | ? | ? | ? | ? |
CSAR9 | ? | ? | ? | ? | ? |
CSAR13 | ? | ? | ? | ? | ? |
50k+A4 | ? | ? | ? | 630 | ? |
- GaAs: Uniform clearing
- InP: Uniform clearing
- InAs: Uniform clearing
- Si: Optimal contrast
Note
Base dose does not change with resist thickness, developing time does. However, if the developing time is fixed, say to 60s, a thinner layer of resist will need lower "base dose", since it's being over developed.