Working with KOH

From cleanroom
Revision as of 15:49, 9 September 2026 by Harry (talk | contribs)
Jump to navigation Jump to search

KOH belongs to the family of anisotropic Si-etchants based on aqueous alkaline solutions. The anisotropy stems from the different etch rates in different crystal directions. The {111}-planes are almost inert whereas the etch rates of e.g. {100}- and {110}-planes are several orders of magnitude faster.

At NBI cleanroom, we use as standard a 28% w/w KOH solution. The etch rate and the selectivity towards a SiO2 mask depends on the temperature. We normally use a temperature of 80°C but it may reduce it to, e.g., 60 °C or 70°C for a higher-precision timed etch.

Si(001) temperature Etch rate (μm/min)
60°C 0.4
70°C 0.7
80°C 1.3
Si(110) temperature Etch rate (μm/min)
80°C 2.5
Thermal SiOx temperature Etch rate (μm/min)
60°C 0.0012
80°C 0.0075



Standard Operating Procedure

Mixing KOH (with pellets)

  • Book the HF fumehood in CR1.
It is recommended to use a setup where you can run your process undisturbed
  • Gather all necessary materials and equipment:
    • IKA hotplate with 2L beaker
    • Scale from to shelves
    • Beakers for measuring and mixing
    • KOH pellets
  • Set up equipment
    • Fill 2L beaker with water to create a hotbath and add a magnetic stirring pill
    • Balance the scale
  • Calculate the portions of water and solid KOH pellets that you would like to mix:
    • You are aiming to make a 28% w/w solution
There is no shame on using an online calculator to figure out the ratios.
    • The KOH pellets come in units of xxx grams. Start by weighing an appropriate amount of KOH and store it to the side.
    • Calculate the respective amount of water and fill a beaker with it.
  • Slowly add the KOH pellets to the water a few at a time while stirring gently.
  • Continue stirring until the pellets dissolve completely
  • Place your solution in the hotbath
  • Place a second beaker with MQ next to it
  • Submerge the probe heater into the MQ beaker
  • Start the stirring and set the temperature.
  • Once you reach the desired temperature, you can start etching your sample