Created page with "There is a number of common computers at QDev/NBI cleanroom for shared use. Please be mindful that a lot of other people want to use them. So, always book before starting to use a PC. Clean up after yourself -- do not leave windows open and programs running once you are done. Do not use flash drives or other removable media. Use N-Drive instead. = Design PCs = There are 4 PCs dedicated to CAD and EBL prep work, so-called ''Design PCs'', named Design 5 through 8. They a..."
 
No edit summary
 
Line 55: Line 55:
; [[BEAMER]] frozen/non-responsive/seemingly not doing anything?
; [[BEAMER]] frozen/non-responsive/seemingly not doing anything?
: Restart Design 7 (it runs the license server). This fixes most software errors and hang-ups.
: Restart Design 7 (it runs the license server). This fixes most software errors and hang-ups.
== Remote access ==
TeamViewer: DESIGN5, DESIGN6, DESIGN7, DESIGN8
= Cleanroom PCs =
There is a number of PCs connected to cleanroom tools.
Cleanroom staff is responsible for those.
They are used to control fabrication related systems and/or transfer data between them and N-drive.
Do not use flash drives or other removable media.
== Remote access ==
All the requests are handled via the KUIT webpages. Log in with your credentials at the following webpage [https://identity.ku.dk identity.ku.dk].
* Click on <code> Manage user access</code>
* <code> Select Users</code> : find your name  and click next
* Search:
** <code>SGT-FORSK_S4_NBI_CLEANROOM-USER</code> for remote access
** <code>N-SCI-NBI-Cleanroom-W</code> for N-Drive access
* Select the service that you would like to get access
* <code> Review and Submit</code>: Press submit
* One of the cleanroom administrators will approve your request.
[[Category:General Lab Business]]
[[Category:Software]]
[[Category:Cleanroom]]

Latest revision as of 11:24, 3 September 2025

There is a number of common computers at QDev/NBI cleanroom for shared use. Please be mindful that a lot of other people want to use them. So, always book before starting to use a PC. Clean up after yourself -- do not leave windows open and programs running once you are done.

Do not use flash drives or other removable media. Use N-Drive instead.

Design PCs

There are 4 PCs dedicated to CAD and EBL prep work, so-called Design PCs, named Design 5 through 8. They are located in 321. They have N-Drive access.

Booking rules

Booking is mandatory on the booking system, schedule 3rd Design, regardless of whether the work is performed locally or remotely.

CAD software

You are free to use any software you please to make your designs. You are not limited to this list.

Cleanroom/IT staff does not provide support for using CAD software.

IT staff is responsible for maintaining licenses for CAD software at QDev/NBI.

Visual design

If you want to have a visual editor and draw the design yourself, the following CAD software is available on the design PCs:

  • AutoCAD
  • KLayout
  • DesignCAD
  • LayoutEditor
  • Clewin

All of the above is already installed on the Design PCs on the 3rd floor, room 321. It may be possible to get them running on your own PC.

Parametric design

If you wish to write code that generates your design, these software libraries are available online:

EBL software

Cleanroom staff is responsible for EBL-related software.

EBL-related processing software (only Design 5 & 7):

Troubleshooting

WeCaS 100 kV is suddenly behaving like WeCaS 125 kV!
  1. Start regedit.exe
  2. Delete all parameters under HKEY_CURRENT_USER/Software/Elionix,Inc./WecaS/Setting
  3. Set "Deny" permissions for the registry folder for the current user
BEAMER frozen/non-responsive/seemingly not doing anything?
Restart Design 7 (it runs the license server). This fixes most software errors and hang-ups.